Customization: | Available |
---|---|
Warranty: | 3years |
Application: | Home |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
4KW Complete Off grid solar system
|
|
|
|
|||
No
|
Item
|
Specification
|
Quantity
|
|||
1
|
Solar panel
|
12V 195W Monocrystalline Solar Panel
|
20 pcs
|
|||
2
|
PV combiner box
|
6 String PV Combiner Box
|
1 pc
|
|||
3
|
Hybrid Inverter
|
3500W 48V Hybrid Inverter
|
1 pc
|
|||
4
|
Battery
|
12V 100AH Lithium Battery
|
8 pcs
|
|||
5
|
Components
|
Z-Bracket
|
20 pcs
|
|||
6
|
Cable
|
16.4 ft 11AWG Sola Extension Cable
|
4 pairs
|
|||
6
|
Cable
|
16ft 8AWG Solar Controller cable
|
1 pc
|
|||
|
|
1.14ft 5AWG Lithium Battery Cable
|
3 pairs
|
All in one charger inverter model
|
HF4830S60
|
HF4840S60
|
HF4850S80
|
HF4825U60
|
HF4830U60
|
HF4820U60
|
||||||
AC mode
|
|
|
|
|
|
|
||||||
Rated input voltage
|
220/230Vac
|
|
|
110/120Vac
|
|
|
||||||
Input voltage range
|
(170Vac~280Vac)±2%/(90Vac~280Vac)±2%
|
|
|
(90Vac~140Vac)±2%
|
|
|
||||||
Frequency
|
50Hz/60Hz(Auto dection)
|
|
|
|
|
|
||||||
Frequency range
|
47±0.3Hz ~55±0.3Hz (50Hz)/57±0.3Hz~65±0.3Hz(60Hz)
|
|
|
|
|
|
||||||
Overload/short circuit protection
|
Circuit breaker
|
|
|
|
|
|
||||||
Efficiency
|
>95%
|
|
|
|
|
|
||||||
Conversion time
|
(bypass and inverter)10ms(typical)
|
|
|
|
|
|
||||||
AC reverse protection
|
Available
|
|
|
|
|
|
||||||
Maximum bypass overload current
|
40A
|
|
|
|
|
|
||||||
Inverter mode
|
|
|
|
|
|
|
||||||
Output voltage waveform
|
Pure sine wave
|
|
|
|
|
|
||||||
Rated output power(VA)
|
3000
|
4000
|
5000
|
2500
|
3000
|
3500
|
||||||
Rated output power(W)
|
3000
|
4000
|
5000
|
2500
|
3000
|
3500
|
||||||
Power factor
|
1
|
|
|
|
|
|
||||||
Rated output voltage(Vac)
|
230Vac
|
|
|
220Vac
|
|
|
||||||
Output voltage error
|
±5%
|
|
|
|
|
|
||||||
Output frequency range(Hz)
|
50Hz±0.3Hz/60Hz±0.3Hz
|
|
|
|
|
|
||||||
Efficiency
|
>90%
|
|
|
|
|
|
||||||
Overload protection
|
(102% < load <125%) ±10%: report error and turn off the output after5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn offthe output after 5 seconds.
|
|
|
|
|
|
||||||
Peak power
|
6000VA
|
8000VA
|
10000VA
|
5000VA
|
6000VA
|
7000VA
|
||||||
Loaded motor capability
|
2HP
|
3HP
|
4HP
|
1HP
|
1HP
|
2HP
|
||||||
Output short circuit protection
|
Circuit breaker
|
|
|
|
|
|
||||||
Bypass breaker specifications
|
40A
|
|
|
|
|
|
||||||
Rated battery input voltage
|
48V(Minimum starting voltage 44V)
|
|
|
|
|
|
||||||
Battery voltage range
|
Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen)
|
|
|
|
|
|
||||||
Power saving mode
|
Load≥25W
|
|
|
|
|
|
||||||
AC charing
|
|
|
|
|
|
|
||||||
Battery type
|
Lead acid or lithium battery
|
|
|
|
|
|
||||||
Maximum charge current
|
60A
|
|
|
30A
|
|
|
||||||
Charge current error
|
±5Adc
|
|
|
|
|
|
||||||
Charge voltage range
|
40~58Vdc
|
|
|
40~58Vdc
|
|
|
||||||
Short circuit protection
|
Circuit breaker and blown fuse
|
|
|
|
|
|
||||||
Circuit breaker specifications
|
40A
|
|
|
|
|
|
||||||
MPPT voltage range
|
60-115Vdc
|
|
|
|
|
|
||||||
Charging short circuit protection
|
Blown fuse
|
|
|
|
|
|
||||||
Wiring protection
|
Reverse polarity protection
|
|
|
|
|
|
||||||
Certification
|
CE(EN62040-1),EMC EN62040-2,C2
|
|
|
|
|
|
||||||
Please contact customer service for more detail information!
|
|
|
|
|
|
|